Fire Resistant Glazing
In a fire protection scenario, the stability of glass under fire conditions is dependent on the capability of the glazing system to resist internal tensions created by the temperature differential across the thickness of the material. Standard glass cracks and shatters when the temperature differential exceeds 40°C. Promat SYSTEMGLAS® and PROMAGLAS®, however, resist temperature differentials up to 1000°C.

The design of the complete glazing system is just as important as the qualities of the glass itself. Promat has developed various high performance systems which not only perform well in fire but also resists smoke, impact, crowd pressure, wind loads, sound transmission and the adverse effects of ultraviolet light.

General Design Considerations
When considering the performance requirements of fire resisting glazing screens and doors, a wide range of Building Regulations, Codes of Practice, Design Guides and test standards have to be factored into the fire protection equation.

  • Sound attenuation
  • Impact resistance
  • Stuctural performance when subjected to pressure of people
  • Manifestations of glazing
  • Wind loading
  • Fire performance (including smoke)
  • Tolerance to ultraviolet light
  • Extreme climatic conditions
  • Bomb or blast resistance
Fire Resistant Insulated Glass - PROMACLEAR® 120
PROMACLEAR® 120 Glass Fire Door and Screen
  • 240 minutes fire resistance FRL -/240/-


Fire Resistant Insulated Glass - PROMAGLAS®
PROMAGLAS® Timber Framed Screens
  • 30 minutes fire resistance FRL -/30/-
  • 60 minutes fire resistance FRL -/60/-

PROMAGLAS® Traditional Insulated Steel Framed Screen
  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -/60/60
  • 90 minutes fire resistance FRL -/90/90
  • 120 minutes fire resistance FRL -/120/120


Fire Resistant Insulated Glass - Promat SYSTEMGLAS®
Promat SYSTEMGLAS® Screens:
All Glass Screens with Vertical Joints

  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -60/60

Promat SYSTEMGLAS® Screens:
All Glass Screens with Horizontal Joints

  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -/60/60

Promat SYSTEMGLAS® Screens:
All Glass Screens with Joints Cover Profiles

  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -/60/60

Promat SYSTEMGLAS® Doors:
All Fire Doors within Glass Screens Single & Double Leaf

  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -/60/60

Note: FRL */*/* (Fire Resistance Limit — *Stability / *Integrity / *Insulation)