Cavity & Smoke Barriers Fire Protection
The purpose of a cavity barrier is to prevent smoke and flame from penetrating and/or moving from one concealed fire compartment to another.

Documents supporting the regulations provide guidance on where such barriers should be located within hidden voids in a building. They usually give examples of deemed-to-satisfy barriers for voids in stud walls or partitions.

If a barrier in a concealed space coincides with a compartment wall or floor it will normally be required to provide the same fire performance as the wall or floor. If the barrier is located between such walls or floors however, the barrier is defined as a "cavity barrier". As such, the barrier will normally and only be required to provide 30 minutes integrity and 15 minutes insulation.

A large cavity barrier is defined as a barrier across a void in which a square with 1m sides can be accommodated. A small cavity barrier is one in which such a square cannot be accommodated. A large cavity barrier is required to provide 30 minutes integrity and 15 minutes insulation. A small cavity barrier need only provide 30 minutes integrity. Cavity barrier definitions are also dependent on the requirements of local building regulations.

General Design Considerations
Following are some factors to consider when determining the correct specification to ensure cavity barriers provide the required fire performance:

  • Size of barrier & location
  • Service penetrations
  • Differential movement
  • Adjoining structure
Parapet / Spandrel Wall
PROMATECT®-H Single Sided Parapet/Spandrel Wall
- Fire attack from either side
  • 120 minutes fire resistance FRL -/120/-

PROMATECT®-H Single Sided Spandrel Wall
- Fire attack from either side
  • 120 minutes fire resistance FRL -/120/-


Smoke Barrier
PROMATECT®-H Smoke Barrier(Board at each side and bottom)
- Fire attack from either side
  • 60 minutes fire resistance FRL -/60/-

PROMINA® 60 Smoke Barrier - Integrity Only (Board at each side and bottom)
- Fire attack from either side
  • 120 minutes fire resistance FRL -/120/-

PROMINA® 60 Smoke Barrier - Integrity & Insulation (Board at each side and bottom)
- Fire attack from either side
  • 120 minutes fire resistance FRL -/120/120

PROMASEAL® Bulkhead Sealer System Single Sided Smoke Barrier
- Fire attack from either side
  • 120 minutes fire resistance FRL -/120/-


Smoke and Fire Barrier
PROMATECT®-S Single Sided Smoke and Fire Barrier (Above Roller Shutter Doors)
- Fire attack from either side
  • 240 minutes fire resistance FRL -/240/-


Cavity Barrier
PROMINA® 60 Cavity Barrier Within Ceiling/Floor Voids (Board at each side and bottom/top)
- Fire attack from either side
  • 30 minutes fire resistance FRL -/30/30
  • 60 minutes fire resistance FRL -/60/60


Fixed Smoke Curtain
PROMINA®-HD Single Sided Fixed Smoke Curtain
- Fire attack from either side
  • 30 minutes fire resistance FRL -/30/-

Note: FRL */*/* (Fire Resistance Limit — *Stability / *Integrity / *Insulation)